{"id":70,"date":"2022-03-07T17:35:18","date_gmt":"2022-03-07T17:35:18","guid":{"rendered":"https:\/\/innovalabinstruments.com\/?page_id=70"},"modified":"2022-04-04T10:40:50","modified_gmt":"2022-04-04T10:40:50","slug":"gc-ms-ms","status":"publish","type":"page","link":"https:\/\/innovalabinstruments.com\/index.php\/analytical-sciences\/gc-ms-ms\/","title":{"rendered":"GC-MS\/MS"},"content":{"rendered":"\n  <div id=\"page-header-1310323189\" class=\"page-header-wrapper\">\n  <div class=\"page-title dark featured-title\">\n\n        <div class=\"page-title-bg\">\n      <div class=\"title-bg fill bg-fill\"\n        data-parallax-container=\".page-title\"\n        data-parallax-background\n        data-parallax=\"-\">\n      <\/div>\n      <div class=\"title-overlay fill\"><\/div>\n    <\/div>\n    \n    <div class=\"page-title-inner container align-center flex-row medium-flex-wrap\" >\n              <div class=\"title-wrapper flex-col text-left medium-text-center\">\n          <h1 class=\"entry-title mb-0\">\n            GC-MS\/MS          <\/h1>\n        <\/div>\n                    <div class=\"title-content flex-col flex-right text-right medium-text-center\">\n        <div class=\"title-breadcrumbs pb-half pt-half\"><nav class=\"woocommerce-breadcrumb breadcrumbs uppercase\">Home<\/nav><\/div>      <\/div>\n    <\/div>\n\n     \n<style>\n#page-header-1310323189 .featured-title {\n  background-color: #d26e4b;\n}\n<\/style>\n  <\/div>\n    <\/div>\n  \n\n\t<section class=\"section\" id=\"section_1030429593\">\n\t\t<div class=\"bg section-bg fill bg-fill  bg-loaded\" >\n\n\t\t\t\n\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row\"  id=\"row-597192482\">\n\n\n\t<div id=\"col-2119233215\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1307560978\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"338\" height=\"338\" src=\"https:\/\/innovalabinstruments.com\/wp-content\/uploads\/2022\/03\/Triple-Quadrupole-GC.png\" class=\"attachment-large size-large\" alt=\"\" srcset=\"https:\/\/innovalabinstruments.com\/wp-content\/uploads\/2022\/03\/Triple-Quadrupole-GC.png 338w, https:\/\/innovalabinstruments.com\/wp-content\/uploads\/2022\/03\/Triple-Quadrupole-GC-300x300.png 300w, https:\/\/innovalabinstruments.com\/wp-content\/uploads\/2022\/03\/Triple-Quadrupole-GC-150x150.png 150w, https:\/\/innovalabinstruments.com\/wp-content\/uploads\/2022\/03\/Triple-Quadrupole-GC-100x100.png 100w\" sizes=\"auto, (max-width: 338px) 100vw, 338px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1307560978 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\n<h3 style=\"text-align: center;\">Triple Quadrupole GC-MS\/MS System coupled with Triplus RSH<\/h3>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1520289796\" class=\"col medium-8 small-12 large-8\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<p>Thermo Scientific <sup>TM<\/sup> TSQ<sup> TM<\/sup> 9000 Triple Quadrupole GC-MS\/MS system delivers high sensitivity for more routine analysis. Minimize maintenance intervaks with routine-grade robustness. Operate with technology, flexible method development and powerful reporting tools designed for optimal productivity. Achieve quality results on tine, every time with easy-to-use routine workflows. Fully upgrade from base to advanced configurations to boost flexibility and performance when you need it.<\/p>\n<p><strong>Specifications:<\/strong><\/p>\n<ul>\n<li>Mass range: 2 to 1100 U with Unit Mass Resolution<\/li>\n<li>Detectors: Triple Off-Axis Thermo Scientific DynaMax XR with Electronic Dynamic Range &gt; 10<sup>9<\/sup><\/li>\n<li>Mass Filter: Dual-Stage Mass Filter with Off-Axis Ion Guide Pre-Filter for Noise Reduction<\/li>\n<li>Modes: Electron Impact Ionization (EI), with Full Scan (FS), SIM, and FS\/SIM, Simultaneous Within The Same Injection, Chemical Ionization (CI) with Positive (PCI) and Negative (NCI) Ion Chemical Ionization, Interchangeable Without Breaking The Vacuu<\/li>\n<li>SRM Transitions Up to 800 SRM Transitions\/s<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"is-divider divider clearfix\" style=\"max-width:900px;background-color:rgb(0, 0, 0);\"><\/div>\n\n<div class=\"row\"  id=\"row-332133838\">\n\n\n\t<div id=\"col-2070991247\" class=\"col medium-8 small-12 large-8\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<h3>Exactive\/Q Exactive GC Orbitrap System<\/h3>\n<p>Bring the power of the first-ever combination of high-resolution gas chromatography (GC) and high-resolution\/accurate-mass (HRAM) Orbitrap mass spectrometry to your laboratory. The Thermo Scientific\u2122 Q Exactive\u2122 GC Orbitrap\u2122 GC-MS\/MS system provides comprehensive characterization of samples in a single analysis for the highest confidence in compound discovery, identification, and quantitation. This system offers the quantitative power of a GC triple quadrupole MS combined with the high precision, full-scan HRAM capabilities only available in combination with Thermo Scientific\u2122 Orbitrap\u2122 technology.<\/p>\n<p><strong>Performance benefits include:<\/strong><\/p>\n<ul>\n<li>Resolving power of up to 100,000 (FWHM) at&nbsp;<em>m\/z<\/em>&nbsp;272<\/li>\n<li>Routine sub ppm mass accuracy<\/li>\n<li>&lt; 6 fg OFN Instrument Detection Limit<\/li>\n<li>EI\/CI Thermo Scientific\u2122 Extractabrite\u2122 ion source removable under vacuum through vacuum interlock<\/li>\n<li>Vent-free column exchange with source plug<\/li>\n<li>Advanced Quadrupole technology (AQT) for superior precursor isolation<\/li>\n<li>Variable electron voltage (VeV) technology for softer EI<\/li>\n<li>High sensitivity MS\/MS experiments with Higher-Energy<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-788265743\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1553512571\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"328\" height=\"290\" src=\"https:\/\/innovalabinstruments.com\/wp-content\/uploads\/2022\/03\/Exactive-Exactive-GC-Orbitrap-System.png\" class=\"attachment-large size-large\" alt=\"\" srcset=\"https:\/\/innovalabinstruments.com\/wp-content\/uploads\/2022\/03\/Exactive-Exactive-GC-Orbitrap-System.png 328w, https:\/\/innovalabinstruments.com\/wp-content\/uploads\/2022\/03\/Exactive-Exactive-GC-Orbitrap-System-300x265.png 300w\" sizes=\"auto, (max-width: 328px) 100vw, 328px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1553512571 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\n<h3 style=\"text-align: center;\">Exactive\/Q Exactive GC Orbitrap System<\/h3>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1030429593 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n#section_1030429593 .ux-shape-divider--top svg {\n  height: 150px;\n  --divider-top-width: 100%;\n}\n#section_1030429593 .ux-shape-divider--bottom svg {\n  height: 150px;\n  --divider-width: 100%;\n}\n<\/style>\n\t<\/section>\n\t\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":793,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"footnotes":""},"class_list":["post-70","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/innovalabinstruments.com\/index.php\/wp-json\/wp\/v2\/pages\/70","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/innovalabinstruments.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/innovalabinstruments.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/innovalabinstruments.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/innovalabinstruments.com\/index.php\/wp-json\/wp\/v2\/comments?post=70"}],"version-history":[{"count":12,"href":"https:\/\/innovalabinstruments.com\/index.php\/wp-json\/wp\/v2\/pages\/70\/revisions"}],"predecessor-version":[{"id":802,"href":"https:\/\/innovalabinstruments.com\/index.php\/wp-json\/wp\/v2\/pages\/70\/revisions\/802"}],"up":[{"embeddable":true,"href":"https:\/\/innovalabinstruments.com\/index.php\/wp-json\/wp\/v2\/pages\/793"}],"wp:attachment":[{"href":"https:\/\/innovalabinstruments.com\/index.php\/wp-json\/wp\/v2\/media?parent=70"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}